operation:operation_and_experience:measurement_results:energy_use_measurement_results
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
operation:operation_and_experience:measurement_results:energy_use_measurement_results [2022/03/04 15:30] – [2.7. Passive House residential building "BuildTog" in Bremen-Findorff] yaling.hsiao@passiv.de | operation:operation_and_experience:measurement_results:energy_use_measurement_results [2022/09/16 12:38] (current) – [Literature] wfeist | ||
---|---|---|---|
Line 141: | Line 141: | ||
===== 2.4. Low-energy house projects in the UK ===== | ===== 2.4. Low-energy house projects in the UK ===== | ||
- | Performance tests of the building envelope were carried out for 25 different buildings. The heat loss per Kelvin temperature difference was determined for the entire building (co-heating test). The measurement by Johnston et al. included 22 low-energy projects and three Passive House buildings [[Operation: | + | Performance tests of the building envelope were carried out for 25 different buildings. The heat loss per Kelvin temperature difference was determined for the entire building (co-heating test). The measurement by Johnston et al. included 22 low-energy projects and three Passive House buildings [[Operation: |
- | [{{ : | + | [{{ : |
\\ | \\ | ||
Line 168: | Line 168: | ||
Completed and inhabited in 2017, the Passive House “BuildTog” in Bremen-Findorff of GEWOBA Bremen has 16 rental apartments with a heated living area of 1,478 m². The solid construction building was planned by the architectural office “Planungsgruppe DREI” from Mühltal near Darmstadt. The building services were planned by “Ingenieurbüro Lachnit” from Roßdorf near Darmstadt. The building is supplied by district heating (heating and hot water), and all apartments are connected by a central ventilation system in the basement. | Completed and inhabited in 2017, the Passive House “BuildTog” in Bremen-Findorff of GEWOBA Bremen has 16 rental apartments with a heated living area of 1,478 m². The solid construction building was planned by the architectural office “Planungsgruppe DREI” from Mühltal near Darmstadt. The building services were planned by “Ingenieurbüro Lachnit” from Roßdorf near Darmstadt. The building is supplied by district heating (heating and hot water), and all apartments are connected by a central ventilation system in the basement. | ||
- | The evaluation of the energy consumption values in the apartments, including the usable | + | The evaluation of the energy consumption values in the flats, including the proportion of usable heat distribution and the minimum |
A residents’ survey shows a very high overall satisfaction with the building in general and the Passive House technology in particular (88% “rather satisfied”, | A residents’ survey shows a very high overall satisfaction with the building in general and the Passive House technology in particular (88% “rather satisfied”, | ||
Line 280: | Line 280: | ||
**[Johnston 2014]** D. Johnston, D. Farmer, M. Brooke-Peat & D. Miles-Shenton (2014): “Bridging the domestic building fabric performance gap”, Building Research & Information, | **[Johnston 2014]** D. Johnston, D. Farmer, M. Brooke-Peat & D. Miles-Shenton (2014): “Bridging the domestic building fabric performance gap”, Building Research & Information, | ||
+ | |||
+ | **[Johnston 2020]** David Johnston, Mark Siddall, Oliver Ottinger, Soeren Peper und Wolfgang Feist: **Are the energy savings of the passive house standard reliable? A review of the as-built thermal and space heating performance of passive house dwellings from 1990 to 2018**; Energy Efficiency (2020) 13: | ||
**[Krellner 2015]** Krellner, Marcus: Jährliche Ablesewerte der Wärmezähler der vier Doppel-haushälften in Nürnberg-Wetzendorf (German only; Annual heat meter readings of four semi-detached houses in Nuremberg-Wetzdorf). Private supply data, July 2015 | **[Krellner 2015]** Krellner, Marcus: Jährliche Ablesewerte der Wärmezähler der vier Doppel-haushälften in Nürnberg-Wetzendorf (German only; Annual heat meter readings of four semi-detached houses in Nuremberg-Wetzdorf). Private supply data, July 2015 |
operation/operation_and_experience/measurement_results/energy_use_measurement_results.1646404209.txt.gz · Last modified: 2022/03/04 15:30 by yaling.hsiao@passiv.de