planning:refurbishment_with_passive_house_components:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components [2014/09/18 18:19] – external edit 127.0.0.1 | planning:refurbishment_with_passive_house_components:prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components [2018/11/05 09:55] (current) – cblagojevic | ||
---|---|---|---|
Line 21: | Line 21: | ||
===== Summary ===== | ===== Summary ===== | ||
- | Based on the examples dealt with in the 24th session of the Research Group for Cost-effective Passive Houses [AkkP 24], Passive House components are also suitable for the modernisation of existing buildings. Their application is both practicable and cost-effective. | + | Based on the examples dealt with in the 24th session of the Research Group for Cost-effective Passive Houses [AkkP 24], Passive House components are also suitable for the modernisation of existing buildings. Their application is both practicable and cost-effective. |
- | These measures | + | |
- | • offer greater security against moisture-related damage, | + | These measures |
- | • improve thermal comfort due to higher surface temperatures | + | • offer greater security against moisture-related damage, |
- | • and double the potential for accessible energy savings | + | • improve thermal comfort due to higher surface temperatures |
- | The attractiveness of a high quality standard of modernisation increases with the use of highly efficient components, as the quality of life | + | • and double the potential for accessible energy savings. \\ |
+ | |||
+ | The attractiveness of a high quality standard of modernisation increases with the use of highly efficient components, as the quality of life | ||
On the other hand, modernisation measures for existing buildings are an important means for stimulating the economy. Thus the measures discussed here represent one of the crucial areas in which economic growth can take place while at the same time relieving the environmental burden. | On the other hand, modernisation measures for existing buildings are an important means for stimulating the economy. Thus the measures discussed here represent one of the crucial areas in which economic growth can take place while at the same time relieving the environmental burden. | ||
With the measures presented here, it is possible to achieve a considerable reduction in CO2 emissions. Improved efficiency in this sector means reduced consumption which enables an increase in the sensible use of renewable energy sources. | With the measures presented here, it is possible to achieve a considerable reduction in CO2 emissions. Improved efficiency in this sector means reduced consumption which enables an increase in the sensible use of renewable energy sources. | ||
- | Other demonstration projects | + | Other demonstration projects |
===== Literature ===== | ===== Literature ===== | ||
Line 53: | Line 55: | ||
**[Michael 2001]** Michael, | **[Michael 2001]** Michael, | ||
Michael, K.; Eichhorn, S. et al.: Efficiency of ventilation systems in low-energy houses in North Rhine-Westfalia, | Michael, K.; Eichhorn, S. et al.: Efficiency of ventilation systems in low-energy houses in North Rhine-Westfalia, | ||
+ | |||
**[Peper 1999]** Peper, | **[Peper 1999]** Peper, | ||
Peper, S., Feist, W.: Airtight planning of Passive houses, CEPHEUS Project Information No. 7, Passive House Institute, Darmstadt, 1999; 4th edition 2002. \\ | Peper, S., Feist, W.: Airtight planning of Passive houses, CEPHEUS Project Information No. 7, Passive House Institute, Darmstadt, 1999; 4th edition 2002. \\ | ||
+ | |||
**[Simons 2000]** Simons, | **[Simons 2000]** Simons, | ||
Simons, P.: Refurbishment of half-timbered construction using 12cm interior insulation; Measurement of moisture-related behaviour over a four-year period, Quadriga 1/2000, page 39ff. | Simons, P.: Refurbishment of half-timbered construction using 12cm interior insulation; Measurement of moisture-related behaviour over a four-year period, Quadriga 1/2000, page 39ff. |
planning/refurbishment_with_passive_house_components/prospects_for_the_modernisation_of_existing_buildings_using_highly_efficient_components.1411057157.txt.gz · Last modified: 2014/09/18 18:19 by 127.0.0.1